{"id":1646,"date":"2025-06-05T00:43:42","date_gmt":"2025-06-04T20:13:42","guid":{"rendered":"https:\/\/anhuma.com\/en\/?post_type=product&#038;p=1646"},"modified":"2025-07-02T11:36:07","modified_gmt":"2025-07-02T07:06:07","slug":"patient-warming-device","status":"publish","type":"product","link":"https:\/\/anhuma.com\/en\/shop\/patient-warming-device\/","title":{"rendered":"Forced Air Patient Warming System with Built-in Serum Warmer"},"content":{"rendered":"<h2 data-start=\"262\" data-end=\"377\"><strong data-start=\"265\" data-end=\"377\">Forced Air Patient Warming System with Built-in Serum Warmer<\/strong><\/h2>\n<p data-start=\"379\" data-end=\"864\"><strong data-start=\"379\" data-end=\"477\">Precision heat management for both patients and intravenous fluids \u2013 all in one advanced unit.<\/strong><br data-start=\"477\" data-end=\"480\" \/>This <strong data-start=\"485\" data-end=\"522\">Forced Air Patient Warming System<\/strong> features a <strong data-start=\"534\" data-end=\"572\">dedicated serum &amp; injection warmer<\/strong>, delivering reliable thermal support across surgical, ICU, and emergency settings. Equipped with a <strong data-start=\"672\" data-end=\"717\">closed-loop temperature monitoring system<\/strong>, <strong data-start=\"719\" data-end=\"737\">service alarms<\/strong>, and an extended <strong data-start=\"755\" data-end=\"791\">temperature range (30\u00b0C to 45\u00b0C)<\/strong>, this system is engineered for patient safety, speed, and long-term use.<\/p>\n<hr data-start=\"866\" data-end=\"869\" \/>\n<h3 data-start=\"871\" data-end=\"894\">\u2705 <strong data-start=\"877\" data-end=\"894\">Core Features<\/strong><\/h3>\n<h4 data-start=\"896\" data-end=\"935\">\ud83d\udd25 <em data-start=\"904\" data-end=\"935\">1. Forced Air Warming Module:<\/em><\/h4>\n<ul data-start=\"936\" data-end=\"1407\">\n<li data-start=\"936\" data-end=\"1004\">\n<p data-start=\"938\" data-end=\"1004\"><strong data-start=\"938\" data-end=\"970\">Temperature Range: 30\u00b0C\u201345\u00b0C<\/strong> \u2013 broader than standard systems<\/p>\n<\/li>\n<li data-start=\"1005\" data-end=\"1066\">\n<p data-start=\"1007\" data-end=\"1066\">Uniform warm air distribution via <strong data-start=\"1041\" data-end=\"1064\">disposable blankets<\/strong><\/p>\n<\/li>\n<li data-start=\"1067\" data-end=\"1142\">\n<p data-start=\"1069\" data-end=\"1142\"><strong data-start=\"1069\" data-end=\"1095\">Closed-loop monitoring<\/strong> for constant, real-time temperature accuracy<\/p>\n<\/li>\n<li data-start=\"1143\" data-end=\"1218\">\n<p data-start=\"1145\" data-end=\"1218\"><strong data-start=\"1145\" data-end=\"1190\">Filter replacement and maintenance alarms<\/strong> for long-term reliability<\/p>\n<\/li>\n<li data-start=\"1219\" data-end=\"1285\">\n<p data-start=\"1221\" data-end=\"1285\"><strong data-start=\"1221\" data-end=\"1247\">HEPA filtration system<\/strong> \u2013 ideal for sterile OR environments<\/p>\n<\/li>\n<li data-start=\"1286\" data-end=\"1349\">\n<p data-start=\"1288\" data-end=\"1349\">Adjustable airflow levels for pre-, intra-, and post-op use<\/p>\n<\/li>\n<li data-start=\"1350\" data-end=\"1407\">\n<p data-start=\"1352\" data-end=\"1407\">Compatible with standard and pediatric warming blankets<\/p>\n<\/li>\n<\/ul>\n<h4 data-start=\"1409\" data-end=\"1458\">\ud83d\udca7 <em data-start=\"1417\" data-end=\"1458\">2. Integrated Serum &amp; Injection Warmer:<\/em><\/h4>\n<ul data-start=\"1459\" data-end=\"1750\">\n<li data-start=\"1459\" data-end=\"1532\">\n<p data-start=\"1461\" data-end=\"1532\">Rapid warming for <strong data-start=\"1479\" data-end=\"1530\">100\u2013500 ml IV bags, syringes, and serum pouches<\/strong><\/p>\n<\/li>\n<li data-start=\"1533\" data-end=\"1580\">\n<p data-start=\"1535\" data-end=\"1580\"><strong data-start=\"1535\" data-end=\"1578\">Independent digital temperature control<\/strong><\/p>\n<\/li>\n<li data-start=\"1581\" data-end=\"1645\">\n<p data-start=\"1583\" data-end=\"1645\"><strong data-start=\"1583\" data-end=\"1607\">Closed-loop feedback<\/strong> ensures fluid temperature stability<\/p>\n<\/li>\n<li data-start=\"1646\" data-end=\"1699\">\n<p data-start=\"1648\" data-end=\"1699\">Built-in <strong data-start=\"1657\" data-end=\"1674\">safety alarms<\/strong> to prevent overheating<\/p>\n<\/li>\n<li data-start=\"1700\" data-end=\"1750\">\n<p data-start=\"1702\" data-end=\"1750\">Digital readout with <strong data-start=\"1723\" data-end=\"1750\">visual &amp; audible alerts<\/strong><\/p>\n<\/li>\n<\/ul>\n<hr data-start=\"1752\" data-end=\"1755\" \/>\n<h3 data-start=\"1757\" data-end=\"1781\">\ud83c\udfe5 <strong data-start=\"1764\" data-end=\"1781\">Designed For:<\/strong><\/h3>\n<ul data-start=\"1782\" data-end=\"1931\">\n<li data-start=\"1782\" data-end=\"1817\">\n<p data-start=\"1784\" data-end=\"1817\">General and specialty surgeries<\/p>\n<\/li>\n<li data-start=\"1818\" data-end=\"1855\">\n<p data-start=\"1820\" data-end=\"1855\">Anesthesia preparation &amp; recovery<\/p>\n<\/li>\n<li data-start=\"1856\" data-end=\"1889\">\n<p data-start=\"1858\" data-end=\"1889\">ICU and emergency departments<\/p>\n<\/li>\n<li data-start=\"1890\" data-end=\"1931\">\n<p data-start=\"1892\" data-end=\"1931\">Pediatric, geriatric, and oncology care<\/p>\n<\/li>\n<\/ul>\n<hr data-start=\"1933\" data-end=\"1936\" \/>\n<h3 data-start=\"1938\" data-end=\"1974\">\ud83d\udee0 <strong data-start=\"1945\" data-end=\"1974\">Technical Specifications:<\/strong><\/h3>\n<div class=\"_tableContainer_80l1q_1\">\n<div class=\"_tableWrapper_80l1q_14 group flex w-fit flex-col-reverse\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"1976\" data-end=\"2855\">\n<thead data-start=\"1976\" data-end=\"2063\">\n<tr data-start=\"1976\" data-end=\"2063\">\n<th data-start=\"1976\" data-end=\"2012\" data-col-size=\"sm\">Feature<\/th>\n<th data-start=\"2012\" data-end=\"2063\" data-col-size=\"md\">Description<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"2152\" data-end=\"2855\">\n<tr data-start=\"2152\" data-end=\"2239\">\n<td data-start=\"2152\" data-end=\"2188\" data-col-size=\"sm\">Temperature Range<\/td>\n<td data-col-size=\"md\" data-start=\"2188\" data-end=\"2239\">30\u00b0C \u2013 45\u00b0C (air &amp; fluid modules)<\/td>\n<\/tr>\n<tr data-start=\"2240\" data-end=\"2327\">\n<td data-start=\"2240\" data-end=\"2276\" data-col-size=\"sm\">Fluid Warming Capacity<\/td>\n<td data-col-size=\"md\" data-start=\"2276\" data-end=\"2327\">100ml \u2013 500ml<\/td>\n<\/tr>\n<tr data-start=\"2328\" data-end=\"2415\">\n<td data-start=\"2328\" data-end=\"2364\" data-col-size=\"sm\">Control Interface<\/td>\n<td data-col-size=\"md\" data-start=\"2364\" data-end=\"2415\">Dual digital screens with touch\/knob input<\/td>\n<\/tr>\n<tr data-start=\"2416\" data-end=\"2503\">\n<td data-start=\"2416\" data-end=\"2452\" data-col-size=\"sm\">Monitoring System<\/td>\n<td data-col-size=\"md\" data-start=\"2452\" data-end=\"2503\"><strong data-start=\"2454\" data-end=\"2490\">Closed-loop temperature feedback<\/strong><\/td>\n<\/tr>\n<tr data-start=\"2504\" data-end=\"2591\">\n<td data-start=\"2504\" data-end=\"2540\" data-col-size=\"sm\">Alarms<\/td>\n<td data-col-size=\"md\" data-start=\"2540\" data-end=\"2591\">Safety (temp), Filter\/Service, Fluid overheat<\/td>\n<\/tr>\n<tr data-start=\"2592\" data-end=\"2679\">\n<td data-start=\"2592\" data-end=\"2628\" data-col-size=\"sm\">Filter Type<\/td>\n<td data-col-size=\"md\" data-start=\"2628\" data-end=\"2679\">Medical-grade HEPA<\/td>\n<\/tr>\n<tr data-start=\"2680\" data-end=\"2767\">\n<td data-start=\"2680\" data-end=\"2716\" data-col-size=\"sm\">Power Supply<\/td>\n<td data-col-size=\"md\" data-start=\"2716\" data-end=\"2767\">220V \/ 50\u201360Hz<\/td>\n<\/tr>\n<tr data-start=\"2768\" data-end=\"2855\">\n<td data-start=\"2768\" data-end=\"2804\" data-col-size=\"sm\">Hose Length<\/td>\n<td data-col-size=\"md\" data-start=\"2804\" data-end=\"2855\">2.5\u20133 meters<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Forced Air Patient Warming System with Built-in Serum Warmer Precision heat management for both patients and intravenous fluids \u2013 all<\/p>\n","protected":false},"featured_media":1646,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_cat":[39],"product_tag":[],"class_list":["post-1646","product","type-product","status-publish","has-post-thumbnail","product_cat-anesthesia","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/anhuma.com\/en\/wp-json\/wp\/v2\/product\/1646","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/anhuma.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/anhuma.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/anhuma.com\/en\/wp-json\/wp\/v2\/comments?post=1646"}],"version-history":[{"count":3,"href":"https:\/\/anhuma.com\/en\/wp-json\/wp\/v2\/product\/1646\/revisions"}],"predecessor-version":[{"id":1728,"href":"https:\/\/anhuma.com\/en\/wp-json\/wp\/v2\/product\/1646\/revisions\/1728"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/anhuma.com\/en\/wp-json\/wp\/v2\/product\/1646"}],"wp:attachment":[{"href":"https:\/\/anhuma.com\/en\/wp-json\/wp\/v2\/media?parent=1646"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/anhuma.com\/en\/wp-json\/wp\/v2\/product_cat?post=1646"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/anhuma.com\/en\/wp-json\/wp\/v2\/product_tag?post=1646"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}